Project Description
DP9000 series compact high-voltage wire/cable harness tester has a maximum voltage of 5kV AC/6kV DC. The volume is greatly reduced compared to the first generation of high-voltage wire harness tester and can be used for distributed high-voltage wire harness testing.
The tester is used in testing various high-voltage wire harness, high-voltage connector, automotive mainline board (Flexible circuit boards for new energy vehicles), automotive power distribution unit (PDU) control box, AC/DC charging gun and AC/DC charging station, etc.
- Precise four-wire test measurement (equipped with contact verification of temperature compensation foolproof four wire fixture)
- Support distributed testing up to 20,480 points
- On-state resistance resolution 10Μω
- Available two-wire and four-wire test
- AC/DC hipot test (Dielectric withstand voltage) up to 5000V
- Board modular design
- LCR test frequency: 50Hz~100kHz
- Insulation test up to 10GΩ
- A multifunctional IO board to achieve one-stop test in charging guns/PDUs
- Automatic grasping high-voltage points
- Automatic self-learning for conduction points
- Easy to understand settings and editing
- Support bar code scan and print function
- Local database and docking with MES
- Multimeter offers point-to-point verification test
- Device self-checking and automatic point finding, point alias naming
- Prite report in PDF format
- I/O interface customization
- Safety grating to prevent electric shock (horizontal)
- Support voice broadcast points and visually graphic edit
- Tests of high-voltage cables and connectors for electric vehicles
- PDU test for electric vehicles
- AC/DC charging gun and station test
- Rail transit distributed test
- Military and nuclear cable test
Model | DP9000 | ||
Measuring Mode | Inner four-wire + outer four-wire | ||
Maximum number of test points | 80 | ||
AC Output Voltage | 50-5kV AC | ||
DC Output Voltage | 50-6kV DC | ||
High Voltage Output Accuracy | ±3% | ||
High Voltage Measurement Accuracy | ±3% | ||
High Voltage Measurement Time | 0.02s – 60s, user delay not included | ||
Low Voltage Measurement Time | 0.02s – 60s, user delay not included | ||
O/S Measurement Time | 300mS (80 points, user delay not included) | ||
Test items and range | O/S, Intermittence O/S, Quick Intermittence Open Circuit |
2kΩ-100 kΩ | |
Inner Four-wire Test Conductance | 0.1Ω-1MΩ | ||
Outer Four-wire Conductance Test | Measurement Range | 1μΩ-100Ω | |
Current Signal | ≤1A | ||
AC Hipot Leakage Current | 0.01mA-10mA | ||
DC Hipot Leakage Current | 0.1μA-5mA | ||
DC Hipot Insulation Resistance | 1MΩ-5GΩ | ||
Measurement Range | 100mΩ-20MΩ | ||
DC Resistance | Level Signal | 0-5V | |
Current Signal | ≤10mA | ||
Capacitances Measurement Range | 10pF-100mF | ||
Resistance Neasurement Range | 100mΩ-20MΩ | ||
LCR | Inductance Measurement Range | 10nH~100H | |
Frequency Signal | 50Hz/60Hz/100Hz/120Hz/1kHz/10kHz/10kHz | ||
Range Mode | AUTO/HOLD | ||
Level Signal | 0.1/0.3V/1V | ||
Dioden/Zener diodes | Test Range | 0-80V | |
Test Signal | 1mA/80V | ||
Single-Side Test | Yes | ||
O/S Terminal Judge | Yes | ||
Advanced Functions | Programmable continuous test/ Automatic point search/ Auto-diagnosis | ||
Test Scan Mode | Automatic/manual/external | ||
Measurement Signal | low voltage measurement signal | ||
Storage Memory | Number of test file up to 500 sets | ||
OS Voltage | 5V | ||
Panel | System/ Rapid/ Edit/ Function | ||
Indicator | Pass/ Fail HV LED/ red-green indicator lights/ Screen Display/ Sound | ||
Dimension (W*H*D) | 500*420*400 mm | ||
Weight | 25 kg |